Hot Insulation Jacket Grey Removable Check Valve Silicone Coated Cover
Unionfull removable fiberglass thermal insulation jackets protect devices from harsh environmental conditions and various vibrations. Insulation cover also provide protection against freezing and overheating.
Insulation is typically removed from components such as gate valves, steam traps and wye strainers due to component maintenance or repair. And these components are usually never reinsulated. But removable insulation jacket is designed for dry or wet applications. It is produced to insulate pipe components including but not limited to gate valves, globe valves, PRVs, steam traps, unions, flanges, etc. If you’re looking to save money, increase workplace comfort, or simply keep your equipment running smoothly, insulation jacket cover can help.
Insulating Check Valves. Because of various design and size of check valves, it is common for check valves to be uninsulated. This situation can lead to uneven distribution of stress on check valves in factory systems. Due to its importance as a component in a larger system, a check valve failure can be catastrophic for a factory operator. For this reason, it is necessary to ensure that stress on factory systems is as equally dispersed as possible. What's more, check valves in high temperature systems often serve as a significant point from which valuable heat can escape. With Unionfull removable insulation jackets of check valves, your factory can benefit from insulated componentry without worrying about uneven stress dispersal.
Properties
Data Sheet
Item Name | Removable Insulation Cover | ||||||||
Fit | Check Valve and others | ||||||||
Thickness | 25mm | ||||||||
Size | Customized | ||||||||
Outside Materials | Name | Silicone Coated Fiberglass Cloth | |||||||
Work Temperature | Fiberglass Cloth: 550℃ | ||||||||
Silicone Coating:260℃ | |||||||||
Inside Materials | Name | Fiberglass Needle Mat | |||||||
Work Temperature | 800℃ Continuously | ||||||||
Anticipated Touch Temperature | Surface: 30-45℃ |
IR Test
IR Test result of removable jacket showed that when the temperature in equipment goes up to 300℃ continuously, the surface temperature of this jacket is around 35℃.